Determine the cop of a refrigerator

WebDisregarding any heat transfer and pressure drops in the connecting lines between the components, Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 MPa and -10°C at a rate of 0.05 kg/s and leaves at 0.8 MPa and 50°C. The refrigerant is cooled in the condenser to 26°C and 0.72 MPa and is throttled to 0.15 MPa. Web1. A Carnot heat engine operates between a heat source at 1300 K and the environment at 300 K.The net work produced by the engine is used to power a Carnot refrigerator which removes heat, from a cooled space at − 2 2 ∘ C at a rate of 370 kJ / min and rejects it to the same environment at 300 K.Determine a) the entropy changes of the heat sources in the …

Coefficient of Performance – COP – Refrigerator, Air …

WebIn a refrigeration cycle, the desired output is Q C, because the goal is to remove heat from the cold reservoir. The required input is the work input, W ref. So, COP R = Q C over W ref. Next we use the 1st Law to eliminate … WebFeb 22, 2024 · A food refrigerator is to provide a 15,000 kj/h cooling effect while rejecting 22,000 kj/h of heat. calculate the cop of this refrigerator. ... Advertisement taskmasters taskmasters Coefficient of performance or more commonly known as COP is calculated through the equation, COP = ((T₂)/(T₂ - T₁)) where T₂ is the hot temperature and T₁ ... howdens kitchen appliances price https://thinklh.com

What is Coefficient of Performance - COP - Refrigerator, …

WebQuestion 3 (1 point) A refrigerator accepts heat at a rate of 10 kW and it consumes power (work) at a rate of 5 kW. Determine the COP of the refrigerator. O 0.50 15 kW 2.0 kW 05 kW ; Question: Question 3 (1 point) A refrigerator accepts heat at a rate of 10 kW and it consumes power (work) at a rate of 5 kW. Determine the COP of the refrigerator. WebApr 5, 2024 · A refrigerator using R-134a rnaintains the ternperature of its compartment at -10°C while ambient temperature A 35°C. Make reasonable assumptions and a) Determine how the pressure levels should change if we replace the working fluid with propane, Orb) Recommend whether propane or R-134a should be used, considering the COP. WebThe food compartment of a refrigerator, shown in Fig. 6-24, is maintained at 4°C by removing heat from it at a rate of 360 kJ/min. If the required power input to the refrigerator is 2 kW, determine (a) the coefficient of performance of the refrigerator and (b) the rate of heat rejection to the room that houses the refrigerator. howdens kitchen appliances sale

COP-Based Performance Evaluation of Domestic Refrigerators …

Category:Solved 1. A Carnot heat engine operates between a heat - Chegg

Tags:Determine the cop of a refrigerator

Determine the cop of a refrigerator

11.8: Heat Engines and Refrigerators - Physics LibreTexts

WebThe coefficient of performance (COP) is a measure of efficiency of the refrigerator. The COP of a domestic refrigerator is the ratio of the refrigeration capacity to the energy supplied to the compressor. It can be expressed by equation 3 (Dossat, 1978; Dincer, 2003). P Q in COP 2 1 1 4 m h h m h h (3) WebME354 Thermodynamics 2 Quiz #3 - T02: Name: ID #: Problem: A commercial refrigerator with refrigerant- 134a as the working fluidisusedtokeepthe refrigerated space at −30 C by rejecting its waste heat to cooling water that enters the condenser at 18 C at a rate of 0.25kg/sand leaves at 26 C.The refrigerant enters the condenser at 1.2MPa and …

Determine the cop of a refrigerator

Did you know?

http://labman.phys.utk.edu/phys136core/modules/m3/refrigerators.html#:~:text=For%20a%20refrigerator%20the%20coefficient%20of%20performance%20is,low%20%2FCOP%20%3D%20120%2F5%20J%20%3D%2024%20J. WebMar 31, 2024 · The Coefficient of Performance (COP) is defined by the ratio of heat dissipation and electrical power intake. It is the parameter by which the air conditioning unit’s performance is evaluated. It shows how effective heating and cooling systems are, following points show the characteristics of COP,

Webperformance (COP): net in H HP net in L R W Q COP W Q COP,, The Reversed Carnot Cycle Reversing the Carnot cycle does reverse the directions of heat and work interactions. A refrigerator or heat pump that operates on the reversed Carnot cycle is called a Carnot refrigerator or a Carnot heat pump. WebThe coefficient of performance (COP) of reversible or irreversible refrigerator or heat pump is given by. COP R = 1/ ( (Q H /Q L )-1) COP HP = 1/ (1- (Q L /Q H )) where. Q H = the amount of heat rejected to the. high-temperature reservoir. Q L = the amount of heat received from the. low-temperature reservoir.

WebQuestion: Determine the COP of a refrigerator that removes heat from the food compartment at a rate of 5140 kJ/h for each kW of power it consumes. Also, determine the rate of heat rejection to the outside air. (Round the final answers to two decimal places and the nearest whole number, respectively.) The COP is .................. .

WebDetermine the COP of a vapor-compression refrigerator implementing the simple inverse Rankine cycle, employing R134a as refrigerant, with saturated vapor leaving the evaporator at 278 K and saturated liquid leaving the condenser at 300 K. The compressor has an isentropic efficiency of 0.87.

WebIt includes measurements of the thermal insulation of a typical refrigerator cabinet (1.21 W/K for the freezer, 0.88 W/K for the refrigerated compartment). From Table 3 of that publication, I find a COP of about 1.7 - suggesting that for our example 1.7*25 W = 42 W of heat is extracted, and 42W+25W = 67 W is rejected how many rings do the jets haveWebSince the ratio of heat removed to work input is defined as the COP of a refrigerator, this corresponds to a COP of 1.8. ... Using this equation with COP = 1.8 and T 0 = 25°C, we determine T = −81.3°C. This is the temperature a heat reservoir would have if a Carnot refrigerator with a COP of 1.8 operated between this reservoir and another ... howdens kidlington phone numberWebOct 9, 2024 · We can calculate a refrigerator coefficient of performance (COP r) in two ways: Dividing the amount of heat removed from the … how many rings do thymine and cytosine haveWebMar 17, 2015 · Coefficient Of Performance (COP) is the ratio of "Coldness" produced to the "Heat" or " Work" supplied. In the case of vapour compression system, it is the mechanical or electrical work , … howdens kitchen breakfast barWebMechanical Engineering questions and answers. Determine the COP of a refrigerator that removes heat from the food compartment at a rate of 5080 kJ/h for each kW of power it consumes. Also, determine the rate of heat rejection to the outside air. The COP of the refrigerator is The rate of heat rejection to the outside air is kJ/h. d <. howdens kitchen cabinet pricesWebTranscribed Image Text: A refrigerator uses refrigerant-134a as the working fluid and operates on the ideal vapor- compression refrigeration cycle except for the compression process as shown in Figure Q1. The refrigerant enters the evaporator at 120 kPa with a quality of 34 percent and leaves the compressor at 70°C. If the compressor consumes … how many rings do the mets haveWebA household refrigerator runs one-fourth of the time and removes heat from the food compartment at an average rate of 800 kJ/n. If the COP of the refrigerator is 2.3, determine the power the refrigerator draws when running. 300 Wh COP Refrigerator The power the refrigerator draws when running is KW howdens kitchen catalogue